Results 1 - 20 de 25
Filter
1.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
2.
Rev. bras. oftalmol ; 78(6): 364-369, nov.-dez. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057914

ABSTRACT

Abstract Objective: The EX-PRESS device is a surgical alternative for the treatment of POAG. To describe the IOP behavior before and after the implantation of the EX-PRESS, the pharmacological treatment used in the pre and postoperative period and the complications in the first year of the postoperative period. Methods: A quantitative descriptive study with review of electronic medical records of a private ophthalmological reference hospital in Goiânia (GO) from 2013 to 2018. Sample composed of 8 eyes with POAG subjected to the EX-PRESS implant. We observed the variables: gender, age, operated eye, antiglaucomatous medications used, pre and postoperative intraocular pressure, and possible complications. Results: In the preoperative period, all eyes used antiglaucomatous drops, 75% used 3 or more different classes simultaneously. After 12 months of EX-PRESS, only 12.5% used three or more eye drops and 37.5% did not use any eye drops. On average, IOP varied from 18.63mmHg (SD 9.38) in the preoperative period to 14.50mmHg (SD 4.14) at 12 months postoperatively. Complications were: ocular hypotension, ocular hypertension; thinning of the conjunctival blister, cystic blister obstruction of the EX-PRESS. We resolved all coplications. Conclusion: The efficacy of EX-PRESS in IOP reduction was verified in the study. Concomitantly, there was a considerable decrease in anti-glaucomatous medications, and few associated complications.


Resumo Objetivo: O dispositivo EX-PRESS é uma alternativa cirúrgica para o tratamento do GPAA. Descrever o comportamento da PIO antes e após a implantação do EX-PRESS, o tratamento farmacológico utilizado no período pré e pós-operatório e as complicações no primeiro ano do pós-operatório. Métodos: Estudo descritivo quantitativo com revisão de prontuários eletrônicos de um hospital particular de referência oftalmológica de Goiânia (GO) no período de 2013 a 2018. Amostra composta por 8 olhos com GPAA submetidos ao implante de EX-PRESS. Foram observadas variáveis: sexo, idade, olho operado, medicações antiglaucomatosas usadas, pressão intraocular pré e pós-operatória, e possíveis complicações. Resultados: No pré-operatório, todos os olhos usavam colírios antiglaucomatosos, 75% faziam uso simultâneo de 3 ou mais classes diferentes. Após 12 meses do EX-PRESS, apenas 12,5% usavam três ou mais colírios e 37,5% não usavam nenhum colírio. Em média, as PIO variaram de 18,63 (DP 9,38) mmHg no pré-operatório para 14,50 (DP 4,14) mmHg em 12 meses do pós-operatório. As complicações foram: hipotensão ocular, hipertensão ocular,afinamento de bolha conjuntival, bolha cística, obstrução parcial do EX-PRESS. Conclusão: A eficácia do EX-PRESS na redução da PIO foi verificada na amostra desse estudo. Concomitantemente, constatou-se diminuição considerável de medicações anti-glaucomatosas, e poucas complicações associadas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma, Open-Angle/surgery , Glaucoma Drainage Implants , Intraocular Pressure/physiology , Tonometry, Ocular/instrumentation , Electronic Health Records
3.
Rev. bras. oftalmol ; 78(3): 162-165, May-June 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1013675

ABSTRACT

RESUMO Objetivo: Comparar o resultado entre dois tipos de tonômetros, tendo como padrão ouro a tonometria de aplanação, relacionando com a espessura corneana e suas validações como instrumentos de rastreio populacional. Métodos: Estudo transversal comparativo, realizado com 400 olhos do ambulatório de oftalmologia da Adachi Oftalmologia, em Macapá (Amapá), entre os valores médios da pressão ocular medidos pelo tonômetro Icare®, o Tonômetro Pneumático e o Tonômetro de Aplanação de Goldmann em função da espessura corneana. Foram divididos conforme a ECC em 3 grupos. Grupo 1: 260 olhos com ECC< 530µ; grupo 2: 217 olhos com ECC entre 530µ e 590µ; e, grupo 3: 157 olhos com ECC>590µ. Resultados: A ECC média obtida na paquimetria foi de 557µ, variando de 651µ a 477µ (desvio padrão de 32.9). A PIO média obtida pela TP foi de 19,4 mmHg (com desvio padrão de 2,32); pelo Icare® foi de 16,7mmHg (desvio padrão de 2,12); e, na TAG foi de 15.5 mmHg (desvio padrão de 2,02). Para paquimetrias inferiores a 530µ e superiores a 590µ a PIOm não diferiu significativamente entre a TAG e Icare® (p = 0,232), sendo estatisticamente significativa diferença obtida para córneas com ECC entre 530 e 590 µ. A PIOm obtida pelo TP foi significativamente maior do que a pressão ocular média dos TAG e Icare® (p < 0,001 para ambos) em todos os grupos. Conclusões: Os três métodos podem ser utilizados em campanhas de rastreamento, porém o Icare® se mostrou mais confiável que a TP, com valores obtidos estatisticamente mais confiáveis quando comparados à TP. Existe suficiente concordância entre o Icare e a TAG para recomendar o seu uso.


ABSTRACT Objective: To compare the result between two types of tonometres, using as gold standard the aplanation tonometry, relating to the corneal thickness and its validations as instruments of population screening. Methods: A comparative cross-sectional study was carried out with 400 eyes from the ophthalmology clinic of Adachi Ophthalmology, in Macapá (Amapá), between the mean values of ocular pressure measured by the Icare® tonometro, the Pneumatic Tonometer and the Goldmann Flattening Tonometro as a function of corneal thickness. They were divided according to ECC in 3 groups. Group 1: 260 eyes with ECC <530µ; group 2: 217 eyes with ECC between 530µ and 590µ; and, group 3: 157 eyes with ECC> 590µ. Results: The mean ECC obtained in pachymetry was 557µ, ranging from 651µ to 477µ (standard deviation of 32.9). The mean IOP obtained by PT was 19.4 mmHg (with a standard deviation of 2.32); by Icare® was 16.7mmHg (standard deviation of 2.12); and in the TAG it was 15.5 mmHg (standard deviation of 2.02). For pachymetry less than 530µ and greater than 590µ, PIOm did not differ significantly between TAG and Icare® (p = 0.232), and a statistically significant difference was obtained for corneas with ECC between 530 and 590 µ. The IOP obtained by the PT was significantly higher than the mean ocular pressure of the TAG and Icare® (p <0.001 for both) in all groups. Conclusions: All three methods can be used in screening campaigns, but Icare® proved to be more reliable than TP, with values obtained statistically more reliable when compared to TP. There is sufficient agreement between Icare and TAG to recommend its use.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/diagnosis , Ocular Hypertension/diagnosis , Intraocular Pressure/physiology , Glaucoma/physiopathology , Cross-Sectional Studies , Air , Equipment Design , Corneal Pachymetry
4.
Rev. bras. oftalmol ; 77(5): 248-254, set.-out. 2018. tab, graf
Article in English | LILACS | ID: biblio-977861

ABSTRACT

Abstract Purpose: To validate the comparative measurements of intraocular pressure performed with IcarePRO tonometer (IPT) in relation to Goldmann applanation tonometer (GAT) and non-contact tonometer (NCT), as well as to evaluate the influence of central corneal thickness (CCT) on these values. Methods: This was a prospective and comparative study conducted during 6 months in the Department of Ophthalmology, Hospital de Braga, Portugal. The study population comprised two groups: healthy adults and adults with primary open angle glaucoma (POAG). The IOP values were obtained by the three tonometers and the order of execution was randomly selected. CCT values were obtained by ultrasonic pachymetry. Results: A total of 168 eyes (74 with diagnosis of POAG and 94 healthy) of 84 patients were included in this study. The mean IOP values obtained by IPT, GAT and NCT were 17.36±3.78 mmHg; 14.59±3.32 mmHg; and 17.04±4.01 mmHg, respectively. The comparison between IPT and NCT did not reveal statistically significant differences in the two groups studied. However, statistically significant differences were obtained between IPT and GAT values (p <0.001). The IOP values, recorded by all the tonometers, were significantly and positivily correlated with the CCT (p <0.001). Conclusion: IOP readings measured by IPT are comparable with those obtained by NCT, but higher than those obtained by the GAT. CCT values are correlated with IOP measurements with IPT, as it does in GAT and NCT, and should be always taken into consideration.


Resumo Objetivo: Validar os valores de pressão intraocular (IOP) realizados com o tonômetro IcarePRO (IPT) em relação ao tonômetro de aplanação de Goldmann (GAT) e tonômetro de sopro (NCP), assim como avaliar a influência da espessura central da córnea (CCT) nesses valores. Métodos: Estudo prospectivo e comparativo realizado durante 6 meses consecutivos no Departamento de Oftalmologia do Hospital de Braga, Portugal. A população estudada compreendeu dois grupos: adultos saudáveis e adultos com glaucoma primário de ângulo aberto (POAG). Os valores de IOP foram obtidos pelos três tonômetros e a ordem de execução foi selecionada aleatoriamente. Os valores de CCT foram obtidos por paquimetria ultrassônica. Resultados: Um total de 168 olhos (74 com diagnóstico de POAG e 94 saudáveis) de 84 pacientes foram incluídos neste estudo. Os valores médios de IOP obtidos pelo IPT, GAT e NCT foram de 17.36±3.78 mmHg; 14.59±3.32 mmHg; e 17.04±4.01 mmHg, respectivamente. A comparação entre IPT e NCT não revelou as diferenças estatisticamente significativas nos dois grupos estudados. No entanto, foram obtidas diferenças estatisticamente significativas entre os valores registados pelo IPT em comparação ao GAT (p <0.001). Os valores de IOP, medidos por todos os tonômetros, foram significativamente correlacionados com a CCT (p <0.001). Conclusão: As leituras de PIO medidas pelo IPT são comparáveis às obtidas pelo NCT, mas superiores às obtidas pelo GAT. Os valores de CCT estão correlacionados com medidas de IOP, tal como acontece com o GAT e NCT, pelo que devem ser levados em considerados.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Intraocular Pressure/physiology , Comparative Study , Glaucoma, Open-Angle/diagnosis , Prospective Studies
5.
Rev. bras. oftalmol ; 77(4): 194-196, jul.-ago. 2018. tab
Article in Portuguese | LILACS | ID: biblio-959104

ABSTRACT

RESUMO Objetivos: Analisar a prevalência da microbiota nos tonômetros de aplanação de Goldmann nos consultórios do SUS e definir o grau de contaminação dos tonômetros e a eficácia da assepsia do cone do tonômetro de aplanação. Métodos: Estudo transversal em que foi realizado a coleta de 60 "swabs", divididos nos três tonômetros de aplanação dos ambulatórios do SUS em dois momentos distintos. No primeiro realizou-se a coleta no início dos atendimentos e no segundo momento, a coleta foi realizada ao final de todos os atendimentos. Todos "swabs" foram colhidos no meio Stuart e foi realizada a cultura em meio de bactérias. Resultados: Das 60 amostras, apenas uma apresentou crescimento de agente patogênico, a Escherichia coli. Conclusão: Independente dos vários métodos que o oftalmologista escolher para realizar a assepsia, a mesma é imprescindível para a manutenção de uma boa saúde ocular do paciente, evitando assim a transmissão e propagação de patógenos por meio do exame oftalmológico e concluímos também que o método utilizado pelo nosso serviço parece ser eficaz nesta profilaxia.


ABSTRACT Objective: Analyze the microbiota prevalence in the Goldmann applanation tonometers in the clinic of the SUS to define the contamination of the tonometers and the efficacy of asepsis of the applanation tonometer cone. Methods: A cross-sectional study was carried out to collect 60 "swabs" divided into the three aplanation tonometers of SUS clinics at two different times. In the first one, the collection will be performed at the beginning of the visits and at the second moment, the collection will be performed at the end of all the visits. All swabs will be harvested in the Stuart medium and culture was carried to sow bacteria. Results: Of the 60 samples, only one showed pathogen growth, Escherichia coli. Conclusion: Regardless of the various ways the ophthalmologist chooses to perform asepsis, it is essential for the maintenance of good patient eye health, thus avoiding the transmission and propagation of pathogens through ophthalmologic examination, and we also conclude that the method used by our patient seems to be effective in this prophylaxis.


Subject(s)
Bacteria/isolation & purification , Bacteria/growth & development , Tonometry, Ocular/instrumentation , Equipment Contamination , Escherichia coli/isolation & purification , Escherichia coli/growth & development , Tonometry, Ocular/adverse effects , Asepsis/methods , Glaucoma/diagnosis , Drug Contamination/statistics & numerical data , Cross-Sectional Studies , Bacteriological Techniques , Equipment Reuse , Fluorescein/adverse effects , Culture Media , Fomites/microbiology , Intraocular Pressure
6.
Rev. bras. oftalmol ; 77(1): 14-19, jan.-fev. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-899111

ABSTRACT

Resumo Objetivo: Avaliar a concordância entre os tonômetros de aplanação de Goldman e pneumático na realização do teste de sobrecarga hídrica (TSH). Métodos: Estudo descritivo transversal composto por uma amostra de 102 olhos proveniente de um hospital particular em Goiânia (GO) entre 2013 a 2016, com avaliação das diferentes pressões intraoculares (PIO) nos tonômetros de aplanação de Goldman e pneumático quando submetidos ao TSH. Resultados: A média de idade foi de 52,17 (± 15,21) anos, sendo que60,8% dos pacientes pertenciam ao sexo feminino e 39,2% ao masculino. A média da espessura da córnea foi de 531,9(± 72,75) micra. Por regressão linear as variaveis idade e espessura da cornea central não ocorreram significancia estatistica entre os dois dispositivos analisados. Conclusão: Observou-se boa concordância nas medições entre os aparelhos de aplanação e o pneumático durante o teste de sobrecarga hídrica, porém necessita-se de novos estudos de maior impacto epidemiológico para confirmação desta assertiva.


Abstract Objective: To evaluate the consonance betweenthe Goldman and pneumática planation to nometers under the effect of the water drink test. Methods: Cross-sectional descriptive study consisting of a sample of 102 eyes from a private hospital in Goiânia (GO) from 2013 to 2015,with na evaluation of different intraocular pressures (IOP) in the Goldman and pneumatic flattening to nometers when submitted to TSH. Results: The average age was 52.17 (± 15.21) years old, 60.8% of the patients were female and 39.2% were male.The mean corneal thickness was 531.9(± 72.75) By linear regression the variables age and corneal thickness did not occur statistical significance between the two devices analyzed. Conclusion: Good agreement was observed in the measurements between the applanation devices and the tire during the water drink test, but new studies with a greater epidemiological impact were required to confirm this assertion.


Subject(s)
Humans , Male , Female , Middle Aged , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Drinking Water/administration & dosage , Glaucoma/diagnosis , Ocular Hypertension/diagnosis , Drinking/physiology , Intraocular Pressure/physiology , Time Factors , Cross-Sectional Studies , Reproducibility of Results , Hospitals, Private , Circadian Rhythm/physiology , Diagnostic Techniques, Ophthalmological , Electronic Health Records , Corneal Pachymetry , Sitting Position
7.
Rev. bras. oftalmol ; 77(1): 34-37, jan.-fev. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-899102

ABSTRACT

Resumo Objetivo: O tratamento com anti-angiogêncios é uma das modalidades mais utilizadas em patologias relacionadas ao edema macular. A injeção intravítrea de um inibidor do VEGF-A tem alta efetividade, porém está relacionada com efeitos adversos, como o aumento da pressão intraocular. O objetivo deste estudo foi avaliar a variação da pressão intraocular (PIO) em pacientes que se submeteram a injeções intravítreas de ranibizumabe, a variação de acordo com facia e com história de injeções prévias. Métodos: Este foi um estudo um estu-do observacional transversal. Foram incluídos todos os pacientes submetidos a injeções intravítreas com diagnóstico de degeneração macular relacionada à idade exsudativa, oclusão de veia central da retina com edema macular, ou edema macular diabético. A pressão intraocular foi aferida antes da injeção, imediatamente após e 30 minutos após a injeção com tonômetro portátil. Resultados Foram realizadas 143 injeções intravítreas, restando para a análise 96 injeções realizadas em 55 participantes. A comparação entre a PIO antes e 30 minutos após a injeção intravítrea mostrou-se estatisticamente significativa com PIO final maior que a inicial (p<0,0001) em pacientes com edema macular diabético. Pacientes fácicos e afácicos não mostraram diferenças significativas com relação a variação da PIO. Quando analisados apenas os participantes que haviam recebido injeções prévias, não foi encontrado uma variação significativa. Conclusão: Concluímos neste estudo que existe uma diferença significativa entre a pressão intraocular antes e 30 minutos após a injeção intravítrea de ranibizumabe em pacientes com edema macular diabético, mos-trando que esse período de tempo não foi suficiente para a regressão da PIO ao valor pré-injeção. Não encontramos diferenças significativas entre outros grupos, comparação entre fácicos e afácicos, nem em pacientes que haviam recebido injeções prévias.


Abstract Objective: Treatment with anti-angiogenic drugs is one of the most widely used modalities of treatment of macular edema related conditions. Intravitreal injection of a VEGF-A inhibitor is highly effective, but is related to adverse effects such as increased intraocular pressure. The objective of this study was to evaluate intraocular pressure (IOP) variation in patients who underwent intravitreal injections of ranibizumab, variation according to phakic/aphakic and history of previous injections. Methods: This was a cross-sectional observational study. All patients submitted to intravitreal injections with diagnosis of exudative age-related macular degeneration, retinal central vein occlusion with macular ede-ma, or diabetic macular edema were included. The IOP was measured before the injection, immediately after and 30 minutes after the injection with a portable tonometer. Results: 143 intravitreal injections were performed, with 96 injec-tions performed in 55 participants. The comparison between IOP before and 30 minutes after intravitreal injection showed to be statistically significant with higher than initial IOP (p <0.0001) in patients with diabetic macular edema. Phakic and aphakic patients did not show significant differences regarding IOP variation. When only those participants who had received previous injections were analyzed, no significant variation was found. Conclusion: We conclude in this study that there is a significant difference between intraocular pressure before and 30 minutes after intravitreal injection of ranibizumab in patients with diabetic macular edema, showing that this period of time was not sufficient for regression of IOP at the pre-injection value . We did not find significant differences between other groups, comparing phakic and aphakic patients, nor in patients who had received previous injections.


Subject(s)
Humans , Male , Female , Aged , Ocular Hypertension/chemically induced , Angiogenesis Inhibitors/pharmacology , Intravitreal Injections/methods , Ranibizumab/pharmacology , Intraocular Pressure/drug effects , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Retinal Vein Occlusion/drug therapy , Macular Edema/drug therapy , Cross-Sectional Studies , Angiogenesis Inhibitors/adverse effects , Angiogenesis Inhibitors/therapeutic use , Ranibizumab/adverse effects , Ranibizumab/therapeutic use , Intraocular Pressure/physiology , Macular Degeneration/drug therapy
8.
Rev. bras. oftalmol ; 75(3): 209-213, tab
Article in Portuguese | LILACS | ID: lil-787693

ABSTRACT

RESUMO Objetivo: Avaliar a utilidade do tonômetro de ar (TA) em estudos populacionais em indivíduos suspeitos de hipertensão ocular, comparando os valores com os fornecidos pelo tonômetro de aplanação de Goldmann (TG). Métodos: Estudo transversal, de amostra probabilística, composta por 11.452 indivíduos e"20 anos, compondo-se uma subamostra dos que apresentaram valores de pressão intraocular (PIO) obtidos com o TA e"20mmHg, nos quais a PIO foi repetida com o TG. Os resultados dos dois tonmetros foram comparados considerando sexo, cor da pele referida, lateralidade, relação escavação/disco (Â0,6; entre e"0,6 e <0,8; e"0,8) e diagnóstico. Foram consideradas três situações: não-portadores de glaucoma (NG), suspeitos (SG) e portadores de glaucoma (CG). Para comparação entre as medidas foi utilizado o teste t de Student para amostras pareadas e o teste de correlação de Pearson para avaliar a associação entre PIO, idade e tonometria. Resultados: Foram detectados 198 indivíduos (339 olhos) com PIOe"20mmHg com o TA, que tiveram a medida repetida com o TG. Foram considerados 233 olhos como NG, 47 olhos como SG e 19 olhos como CG. Em olhos com escavação e"0,8, a medida com TA e TG foram semelhantes. Nos NG e SG, o TA superestimou os valores. Houve associação entre aumento da PIO e aumento da idade com os dois tonmetros. Conclusão: Valores de PIO são superiores com TA comparados ao TG, principalmente quando a PIO é normal. Há concordância entre os métodos quando a PIO é alta e a escavação do nervo óptico é aumentada, o que valida a aplicação do TA em campanhas populacionais.


ABSTRACT Purpose: to evaluate the use of air tonometer (TA) in population studies in individuals suspected of ocular hypertension, comparing values with those provided by the Goldmann Tonometer (GT). Methods: a cross-sectional study was done using a probabilistic sample consisting of 11,452 individuals e"20 years old.A subsample composed by the individuals with IOP values obtained with TA e"20 mmHg was selected, in which IOP was repeated with the GT. The results of both tonometers were compared considering gender, referred color of skin, laterality, cup-to-disc ratio (Â0.6; e"0.6 and <0.8; e"0.8) and diagnosis, considering three situations: without glaucoma (NG), suspected glaucoma (SG) and patients with glaucoma (CG). The Student t test was used for paired samples and the Pearson correlation test to evaluate the association between IOP, age and tonometry. Results: we identified 198 individuals (339 eyes) with IOP e"20mmHg with the TA, who had the measures repeated with the GT. Two hundred and thirty-three eyes were considered as NG, 47 eyes as SG and 19 eyes as CG. In eyes with cup-to-disc ratio e"0.8, the TA and GT measurements were similar. In NG and SG, the TA overestimated values. There was an association between increased IOP and increasing age with both tonometers. Conclusion: IOP values are higher with TA compared to GT, especially when IOP is normal.There is agreement between the methods when IOP is high and the optic nerve excavation is increased, which validates the application of TA in population campaigns.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Tonometry, Ocular/statistics & numerical data , Comparative Study , Glaucoma/diagnosis , Glaucoma/epidemiology , Ocular Hypertension/diagnosis , Ocular Hypertension/epidemiology , Cross-Sectional Studies , Probability , Cornea/physiology , Observational Study , Intraocular Pressure/physiology
10.
Arq. bras. oftalmol ; 78(6): 359-362, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-768172

ABSTRACT

ABSTRACT Purpose: High intraocular pressure (IOP) is an important risk factor for a variety of pediatric ophthalmic conditions. The purpose of this study is to evaluate the feasibility, length of examination, and corneal epithelial damage induced by rebound tonometry (RBT) versus Goldmann applanation tonometry (GAT) in school children. Methods: Healthy children (n=57) participated in a randomized, transversal study with IOP measurement by GAT followed by RBT (study arm 1) or RBT followed by GAT (study arm 2). The number of attempts to acquire a reliable IOP measurement and the length of the examination were quantified. Corneal epithelial damage induced by tonometry was evaluated. Bland-Altman analysis was performed to establish the level of agreement between the two techniques. Results: The IOP was measured in all children with at least one of the devices. In both study arms, more children failed to be examined with GAT than with RBT (26% vs. 4%, and 16% vs. 6%, p<0.001, in study arm 1 and 2, respectively). The length of examination was shorter for RBT than for GAT (67.81 s ± 35.20 s vs. 126.70 s ± 56.60 s; p<0.0001); IOP measurements with RBT in both study arms were higher than those with GAT (15.20 ± 2.74 mmHg vs. 13.25 ± 2.47 mmHg, p=0.0247 and 16.76 ± 3.99 mmHg vs. 13.92 ± 2.08 mmHg, p=0.003, respectively). No difference was observed between RBT and GAT regarding the corneal epithelial damage caused by tonometry. Conclusion: IOP measurement is feasible in a greater number of children with RBT, and the examination was faster than that for GAT. Compared with GAT, RBT tended to overestimate the IOP. None of the methods induced marked corneal epithelial defects.


RESUMO Objetivo: A pressão intraocular (PIO) elevada é um importante fator de risco presente em diversas patologias que acometem crianças. O objetivo deste estudo é avaliar a viabilidade, a duração do exame e o dano epitelial corneano induzido pela tonometria de rebote (RBT) versus a tonometria de aplanação de Goldmann (GAT) em crianças em idade escolar. Métodos: Crianças sem comorbidades (n=57) participaram de um estudo randomizado e transversal com medidas da pressão intraocular com GAT seguido de RBT (sequência 1) ou RBT seguido de GAT (sequência 2). O número de tentativas para adquirir uma medição confiável da pressão intraocular e a duração de exame foi quantificado. Danos epiteliais induzidos pela tonometria foram avaliados. Análise de Bland-Altman foi realizada para estabelecer a concordância entre as duas técnicas. Resultados: A pressão intraocular foi medida em todas as crianças com pelo menos com um dos dispositivos. Em ambas as sequências do estudo, mais crianças não permitiram o exame com GAT (26% vs. 4% e 16% vs. 6%, p<0,001). A duração exame com RBT foi menor (67,81 ± 35,20 s vs. 126,70 ± 56,60 s; p<0,0001). As medições de pressão intraocular com este tonômetro em ambas as sequências do estudo foram mais elevadas do que as medidas adquiridas com GAT (15,20 ± 2,74 mmHg vs 13,25 ± 2,47 mmHg, p=0,0247 e 16,76 ± 3,99 mmHg vs. 13,92 ± 2,08 mmHg; p=0,003, respectivamente). Não foi observada diferença quanto à lesão epitelial corneana induzida pela tonometria com RBT e GAT. Conclusão: A medição da pressão intraocular foi possível em um maior número de crianças com a tonometria de rebote, além de ser um exame mais rápido do que GAT. A pressão intraocular foi superestimada com RBT em comparação com GAT. Nenhum dos métodos induziu defeito epitelial corneano significativo.


Subject(s)
Child , Female , Humans , Male , Cornea/anatomy & histology , Intraocular Pressure/physiology , Tonometry, Ocular/methods , Cross-Sectional Studies , Corneal Injuries/etiology , Corneal Pachymetry/methods , Feasibility Studies , Reference Values , Reproducibility of Results , Statistics, Nonparametric , Time Factors , Tonometry, Ocular/adverse effects , Tonometry, Ocular/instrumentation
11.
Rev. bras. oftalmol ; 73(1): 37-39, Jan-Feb/2014. graf
Article in Portuguese | LILACS | ID: lil-712760

ABSTRACT

Relato de caso de uma paciente, com córnea espessa, por distrofia de Fuchs em fase inicial, ainda com transparência corneana preservada (edema corneano subclínico), associado à pressão intraocular (PIO) normal por tonometria de aplanação de Goldman (TAG), que teve entretanto, o diagnóstico de glaucoma primário de ângulo aberto com base em alterações estruturais do nervo óptico. O estudo tomográfico demonstrou padrão de paquimetria espacial compatível com edema subclínico. O estudo biomecânico da córnea com o ORA (Ocular Response Analyzer, ® Reichert), associado à medida corrigida da PIO, possibilitou o entendimento da influência da córnea, que apesar de mais espessa, levava a uma TAG falsamente reduzida (hipoestimada). O estudo da PIO com sistema de tonografia digital de contorno (PASCAL) corroborou com os achados do ORA. Este exemplo ressalta a importância de novas tecnologias na avaliação de pacientes com suspeita de glaucoma, e destaca que a correção da TAG, com base em algoritmos lineares relacionados com a paquimetria central apenas, pode determinar sérios erros de interpretação clínica.


Case report of a patient, with a thick cornea, for Fuchs dystrophy in its early stages, yet with preserved corneal transparency (subclinical corneal edema), associated with normal intraocular pressure (IOP) by Goldman applanation tonometry (GAT), which was however, the diagnosis of primary open-angle glaucoma on the basis of structural changes of the optic nerve. The tomographic study showed a pattern of spatial pachymetry compatible with subclinical edema. The corneal biomechanical study with ORA (Ocular Response Analyzer, Reichert ®) associated with corrected IOP measurement, allowed the understanding of the corneal influence, which, although thicker, leading to a falsely low TAG (underestimated). The IOP study with tonography system digital (PASCAL) corroborated with the findings of ORA. This example highlights the importance of new technologies in patients' evaluation with suspected glaucoma, and highlights that the correction of TAG, based on linear algorithms related to central corneal thickness alone, can determine serious errors in clinical interpretation.


Subject(s)
Humans , Female , Middle Aged , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/physiology , Cornea/pathology , Corneal Pachymetry/methods , Intraocular Pressure/physiology , Optic Nerve/pathology , Tonometry, Ocular/instrumentation , Tomography , Fuchs' Endothelial Dystrophy/physiopathology , Glaucoma, Open-Angle/diagnosis , Ocular Hypertension/diagnosis , Slit Lamp Microscopy , Gonioscopy
12.
Arq. bras. oftalmol ; 76(6): 354-356, nov.-dez. 2013. graf, tab
Article in English | LILACS | ID: lil-701286

ABSTRACT

PURPOSE: To identify the correlation between the difference of intraocular pressure measurements (IOP) obtained using the Goldmann applanation tonometer (GAT) and three others tonometers (Handheld applanation tonometer - HAT, Dynamic contour tonometer - DCT and Tono-Pen®) with biometric characteristics (corneal diameter, pachymetry, keratometry and axial length) in patients with congenital glaucoma. METHODS: A cross-sectional study was performed on 46 eyes from 46 patients with congenital glaucoma. IOP measurements were obtained in all patients using GAT, HAT, DCT and Tono-Pen®. Keratometry, pachymetry, biometry and corneal diameter measurements were performed after the IOP measurement. The order of the tonometries was randomized. The correlations between the differences of IOP values of GAT and the other tonometers (Delta-IOP), and the different biometric parameters were studied. RESULTS: Tono-Pen® Delta IOP revealed moderate positive correlation to keratometry (r=0.41, p=0.004). The other Delta-IOPs showed no correlation with any of the biometric characteristics evaluated. CONCLUSIONS: IOP differences between GAT (gold standard) and GAT, HAT, DCT or Tono-Pen tonometers seem not to correlate with majority of ocular biometric characteristics. The only exception was the keratometry, which correlated in a positive and moderate way with Tono-Pen® Delta-IOP. This result suggests that the differences of IOP values of Tono-Pen® and GAT increase with the steepness of the cornea.


OBJETIVOS: Identificar correlações entre as diferenças de medições de pressão intraocular (IOP) obtidas usando o tonômetro de aplanação de Goldmann (GAT) e três outros tonômetros (Tonômetro portátil de aplanação - TPA, Tonômetro de contorno dinâmico - TCD e Tono-Pen®) com características biométricas (diâmetro corneano, paquimetria, ceratometria e comprimento axial) em pacientes com glaucoma congênito. MÉTODOS: Estudo transversal prospectivo foi realizado em 46 olhos de 46 pacientes com glaucoma congênito. As medidas de pressão intraocular foram obtidas em todos os pacientes utilizando TAG, TPA, TCD e Tono-Pen®. Ceratometria, paquimetria, biometria e diâmetro corneano foram realizadas após mensuração da pressão intraocular. A ordem da utilização tonômetros foi aleatória. Correlações entre as diferenças de valores de PIO entre cada um dos três tonômetros (PIOs Delta) e o tonômetro de Goldmann e as características biométricas foram analisadas. RESULTADOS: PIO Delta do Tono-Pen®revelou correlação positiva moderada com ceratometria (r=0,41, p=0,004). As outras PIOs Delta não se correlacionaram significativamente com nenhuma das características biométricas. CONCLUSÕES: As diferenças entre as PIOs obtidas pelo TAG (padrão ouro) e TPA, TCD e Tono-Pen®parece não se correlacionar com a maioria das características biométricas. A única exceção foi a ceratometria, a qual se correlacionou de forma positiva e moderada com a PIO Delta do Tono-Pen®. Estes resultados indicam que o aumento da diferença entre a PIO obtida com TAG e Tono-Pen®aumenta com o encurvamento da curvatura corneana.


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Young Adult , Biometry/instrumentation , Cornea/pathology , Glaucoma/congenital , Intraocular Pressure/physiology , Tonometry, Ocular/instrumentation , Biometry/methods , Cross-Sectional Studies , Glaucoma/pathology , Keratoconus/diagnosis , Organ Size , Reference Values , Reproducibility of Results , Tonometry, Ocular/methods
13.
Arq. bras. oftalmol ; 76(4): 229-232, jul.-ago. 2013. graf, tab
Article in English | LILACS | ID: lil-686559

ABSTRACT

PURPOSE: To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS: Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. The Kolmogorov-Smirnov test was applied, and Spearman's correlation test was utilized to evaluate the parameters measured by the Corvis ST and age. RESULTS: Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). All other corvis parameters were not correlated to age. This included DA (p=0.319), intraocular pressure (p=0.854), pachy apex (p=0.066), 1st A time (p=0.959), 2nd A time (p=0.561), 1st Length (0.552), 2nd Length (p=0.697), Wing-Dist (p=0.769), curvature radius HC (p=0.145), curvature radius normal (p=0.513), Vin (p=0.980) and Vout (p=0.592). CONCLUSIONS: In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highest concavity-time, i.e., the time from starting until the highest concavity is reached.


OBJETIVO: Correlacionar os parâmetros derivados da deformação da córnea pelo sistema de tonometria de não-contato integrado com a câmera ultra-rápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) com a idade de pacientes jovens saudáveis. MÉTODOS: Estudo observacional, retrospectivo envolvendo 89 olhos de 89 pacientes. As imagens de Scheimpflug foram feitas pela câmera acoplada ao sistema de tonometria de não-contato (Corvis ST) em cada paciente e os parâmetros utilizados foram: Deformidade de amplitude (DA), paquimetria, pressão intraocular, 1st A time, tempo de concavidade máxima, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, raio de curvatura de maior alcance, raio de curvatura normal, Velocidade de entrada (Vin) e de saída (Vout). Estes parâmetros foram correlacionados com a idade. RESULTADOS: A média de idade dos pacientes foi de 27,50 ± 6,30 anos. O tempo de concavidade máxima alcançada da córnea (HC-time) foi o único parâmetro estudado estatisticamente significante correlacionado com a idade (p=0,04, rs=0,18). O valor p das correlações dos parâmetros derivados do Corvis ST e idade foram: DA (p=0,319), pressão intraocular (p=0,854), paquimetria (p=0,066), 1st A time (p=0,959), 2nd A time (p=0,561), 1st Length (0,552), 2nd Length (p=0,697), Wing-Dist (p=0,769), raio de curvatura de maior alcance (p=0,145), curvature radius normal (p=0,513), Vin (p=0,980) e Vout (p=0,592). CONCLUSÃO: Em olhos saudáveis de pacientes jovens, a idade e os parâmetros pressóricos e biomecânicos da deformação da córnea não foram associados, exceto o tempo de concavidade máxima, que é o tempo do início de aplanação até a concavidade máxima alcançada da córnea.


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Young Adult , Cornea/anatomy & histology , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Age Factors , Biomechanical Phenomena , Intraocular Pressure/physiology , Reference Values , Reproducibility of Results , Retrospective Studies , Time Factors
14.
Journal of Veterinary Science ; : 171-176, 2011.
Article in English | WPRIM | ID: wpr-189396

ABSTRACT

The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anesthesia for an in vivo study. IOP was measured postmortem using direct manometry (measured with an aneroid manometer) and tonometry (measured with a Perkins handheld applanation tonometer). The correlation coefficients (r2 ) for the data from the postmortem manometry and Perkins tonometer study were 0.866 for horses and 0.864 for cattle. In the in vivo study, IOP in horses was 25.1 +/- 2.9 mmHg (range 19.0~30.0 mmHg) as measured by manometry and 23.4 +/- 3.2 mmHg (range 18.6~28.4 mmHg) according to tonometry. In cattle, IOP was found to be 19.7 +/- 1.2 mmHg (range 18.0~22.0 mmHg) by manometry and 18.8 +/- 1.7 mmHg (range 15.9~20.8 mmHg) by tonometry. There was a strong correlation between the IOP values obtained by direct ocular manometry and the tonometer in both horses and cattle. Our results demonstrate that the Perkins handheld tonometer could be an additional tool for accurately measuring IOP in equine and bovine eyes.


Subject(s)
Animals , Cattle/physiology , Eye/physiopathology , Horses/physiology , Intraocular Pressure/physiology , Linear Models , Manometry/instrumentation , Tonometry, Ocular/instrumentation
15.
Arq. bras. oftalmol ; 72(3): 346-350, May-June 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-521469

ABSTRACT

PURPOSE: To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS: Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration error. Only one trained individual made all verifications, with a masked reading of the results. Data on the model, age, daily use, frequency of calibration checking and the nature of the ophthalmic department - private or public - were collected and correlated with the observed errors. RESULTS: One hundred tonometers were checked for calibration. Forty seven percent (47/100) were out of 1 mmHg range at least at one point checking. Tonometers mounted to slit lamp, with less than 5 years, used in less than 20 patients daily, that had a calibration check on a yearly basis, and those from private office exhibit a lower rate of inaccuracy, but only the first variable was statistically significant. Sixty one percent of tonometers on public hospitals were out of calibration. CONCLUSION: Calibration of tonometers in the capital of Brazil is poor; those from general hospitals are worst, and this fact can lead to inaccurate detection and assessment of glaucoma patients, overall in the population under government assistance.


OBJETIVOS: Determinar os erros de calibração dos tonômetros de aplanação de Goldmann em clínicas oftalmológicas de Brasília, Brasil, e correlacioná-los a variáveis relativas ao modelo e à utilização dos aparelhos. MÉTODOS: Tonômetros de clínicas oftalmológicas de Brasília tiveram a calibragem aferida usando um cilindro padrão fornecido pelo fabricante dos aparelhos. Todas as aferições foram realizadas por um só examinador previamente treinado e a leitura das medidas foi mascarada por um observador independente. As medidas foram correlacionadas ao modelo, idade, utilização diária e frequência de aferição da calibração dos tonômetros, bem como o serviço em que o aparelho era utilizado - público ou privado. RESULTADOS: Cem tonômetros foram avaliados. Quarenta e sete por cento (47/100) apresentaram erros de leitura maiores ou iguais a 1 mmHg em pelo menos um ponto de aferição, sendo considerados descalibrados. Tonômetros fixos à lâmpada de fenda, com menos de 5 anos de fabricação, usados em menos de 20 pacientes por dia, que tinham a calibragem aferida ao menos anualmente e que eram utilizados em clínicas privadas apresentaram menos descalibragem, porém apenas a primeira variável foi estatisticamente significante. Sessenta e um por cento dos tonômetros de hospitais públicos estavam descalibrados. CONCLUSÕES: A calibragem de tonômetros avaliados em Brasília é precária. A situação é pior nos aparelhos dos hospitais públicos, podendo levar a erros na detecção e no acompanhamento de pacientes com glaucoma atendidos nesses serviços.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Brazil , Cross-Sectional Studies , Calibration/standards , Equipment Failure Analysis/methods , Hospitals, Private/statistics & numerical data , Hospitals, Public/statistics & numerical data , Ophthalmology , Quality Control , Tonometry, Ocular/standards
16.
Indian J Ophthalmol ; 2006 Dec; 54(4): 261-5
Article in English | IMSEAR | ID: sea-70621

ABSTRACT

PURPOSE: This study was conducted to compare the intraocular pressure (IOP) measurements by the Goldman applanation tonometer (GAT), non contact tonometer (NCT) and the ocular blood flow (OBF) pneumotonometer in different IOP ranges in glaucomatous eyes. The effect of central corneal thickness (CCT) on IOP measurement in chronic glaucomatous eyes using the three different tonometers was also evaluated. MATERIALS AND METHODS: IOP measurements of 130 eyes of primary glaucoma patients were performed using GAT by an ophthalmologist while NCT and OBF-pneumotonometer measurements were performed by an experienced optometrist. The IOP values were compared amongst the three instruments in the three different IOP ranges (0-18 mmHg, > 18 to 25 mmHg, > 25 mmHg). CCT was also measured in all patients. RESULTS: The mean of paired difference between GAT and NCT was 0.9 +/- 3.1 mmHg while that between GAT and OBF-pneumotonometer was 0.3 +/- 3.4 mmHg. The OBF-pneumotonometer and NCT were more affected by corneal thickness (0.41 mmHg and 0.4 mmHg / 10 micro corneal thickness respectively) while GAT was the least affected by corneal thickness (0.3 mmHg / 10 micro corneal thickness) though the difference was not statistically significant ( P =0.42). CONCLUSION: With appropriate correction for corneal thickness the NCT and OBF-pneumotonometer can be used as reliably as GAT in following up glaucomatous patients.


Subject(s)
Adult , Aged , Cornea/pathology , Corneal Topography , Equipment Design , Glaucoma/diagnosis , Humans , Intraocular Pressure , Middle Aged , Observer Variation , Reproducibility of Results , Tonometry, Ocular/instrumentation
17.
Indian J Ophthalmol ; 2006 Jun; 54(2): 95-8
Article in English | IMSEAR | ID: sea-72478

ABSTRACT

PURPOSE: To evaluate the measure of intraocular pressure (IOP) in patients with scarred corneas obtained from the affected and non-affected areas. MATERIALS AND METHODS: Eighteen patients with small maculo-leucomatous corneal opacity following microbial keratitis were prospectively included in the study. Goldmann applanation tonometry was done first on the non-affected corneal surface. ProTon tonometry (PT) was then carried out on the same eye, to obtain IOP measurements from the non-affected (PT1) and the affected area (PT2) of the cornea. The IOP measurements were compared using a two-tail paired t test. RESULTS: The mean of IOP measurements of PT 2 and PT1 was 22 mm of Hg (SD +/- 5.2) and 14.8 mm of Hg (SD +/- 5.4), respectively. The higher reading of PT2 was statistically significant ( P < 0.001). The mean Goldmann applanation tonometry was 14.6 mm of Hg (SD 5.4) and it did not differ significantly ( P = 0.86) from the PT1 readings of 14.8 mm of Hg (SD 5.4). CONCLUSION: In patients with maculo-leucomatous corneal opacity, determination of IOP by ProTon tonometer varies from the affected to the non-affected area. The ProTon tonometer overestimates the level of IOP when it is applied to a leucomatous corneal opacity.


Subject(s)
Adolescent , Adult , Child , Cicatrix/pathology , Cornea/pathology , Corneal Opacity/pathology , Equipment Design , Follow-Up Studies , Humans , Intraocular Pressure/physiology , Middle Aged , Prospective Studies , Reproducibility of Results , Tonometry, Ocular/instrumentation
18.
Arq. bras. oftalmol ; 69(1): 41-45, jan.-fev. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-420816

ABSTRACT

OBJETIVO: Avaliar a influência da espessura corneana central e periférica na medida da pressão intra-ocular (Po) obtida com o Tonopen XL. MÉTODOS: Avaliou-se a Po de 58 olhos de pacientes suspeitos ou portadores de glaucoma crônico simples com o tonômetro de aplanacão de Goldmann e com o Tonopen XL na região central (Tonopen Central) e na periferia corneana (Tonopen Periférico), além da espessura corneana (paquímetro DGH 5100e), também na região central (Paquimetria Central) e na periferia da córnea (Paquimetria Periférica). Compararam-se estatisticamente os grupos Goldmann com Tonopen Central, Goldmann com Tonopen Periférico, Tonopen Central com Tonopen Periférico e Paquimetria Central com Paquimetria Periférica. RESULTADOS: A Po média (n desvio-padrão) em mmHg com o Goldmann foi de 14,6 (n3,3), com o Tonopen Central de 18,9 (n2,9) e com o Tonopen na periferia da córnea de 20,7 (n3,7), tendo sido encontrada diferenca altamente significativa (p<0,0001). A média (n desvio-padrão) da Paquimetria Central em micra foi de 526 (n42,3) e da Paquimetria Periférica foi de 639 (n52,9), sendo esta diferenca altamente significativa (p<0,001). Houve correlacão positiva entre as medidas da Po pelo Goldmann e Tonopen Central (r=0,71, p<0,001) e entre as medidas pelo Goldmann e Tonopen Periférico (r=0,65, p<0,0001) e Tonopen Central e Tonopen Periférico (r=0,64, p<0,0001). CONCLUSÕES: Houve correlacão positiva entre as medidas com o Tonopen XL e o Goldmann, mas a Po média pelo Tonopen foi maior que aquela obtida pelo Goldmann. A Po média pelo Tonopen Periférico foi maior que a pelo Tonopen Central. O Tonopen, além de fornecer valores de Po maiores que o Goldmann, é influenciado pela espessura corneana apresentando valores de Po mais elevados na periferia da córnea que na região central.


Subject(s)
Humans , Cornea/anatomy & histology , Intraocular Pressure , Tonometry, Ocular/instrumentation , Chronic Disease , Corneal Topography , Glaucoma , Regression Analysis , Reproducibility of Results
20.
Article in English | IMSEAR | ID: sea-44707

ABSTRACT

OBJECTIVE: To compare intraocular pressure (IOP) measured by two different instruments, air puff tonometer (APT) versus Goldmann applanation tonometer (GAT), in gas-filled vitrectomized eyes. DESIGN: Three-month, prospective, comparative trial. PARTICIPANTS: Thirty-eight patients (38 eyes), who underwent a pars plana vitrectomy (PPV) with gas injection, were enrolled in the study. INTERVENTION: The IOP was measured by an APT, followed by GAT within 10 minutes by two different, masked investigators. MAIN OUTCOME MEASURES: IOPs were measured by two methods and then were compared. RESULTS: Overall, there was a high correlation between both measurements (r = 0.908, p < 0.05). Using the paired t-test, IOPs measured by the APT (21.69 +/- 9.28 mmHg) and GAT (22.84 +/- 9.84) were not significantly different (p > 0.05). By a subgroup analysis of 17 eyes with IOP measured by a GAT of 21 mmHg or less, the APT readings (15.28 +/- 4.81) and GAT readings (14.47 +/- 3.89) were not significantly different (p > 0.05). Of 21 eyes, with IOP measured by a GAT of 22 mmHg or more, the APT readings (26.88 +/- 8.81) were significantly lower than those obtained by the GAT (29.62 +/- 7.69) (p < 0.05). CONCLUSION: In gas-filled vitrectomized eyes, IOP measurements obtained by an APT correlated well with those obtained by GAT, especially when the IOP was within normal range. However, in eyes with elevated IOP, the APT significantly underestimated the IOP measurement when compared to the gold standard, GAT.


Subject(s)
Aged , Air , Equipment Safety , Female , Follow-Up Studies , Glaucoma/diagnosis , Humans , Intraocular Pressure , Male , Middle Aged , Ocular Hypertension/diagnosis , Postoperative Period , Probability , Prospective Studies , Tonometry, Ocular/instrumentation , Treatment Outcome , Vitrectomy/methods